Thermic Fluid Heaters

 


 
Thermic Fluid heaters
NEOTHERM : Oil / Gas / Solid Fuel Fired fully automatic thermic fluid heaters
Salient Features :-
1) Fully automatic
2) Easy operation & failsafe system.
3) Outside the purview of IBR.
4) Packaged models.
5) 100% depreciation in the first year.
6) Record efficiency.
Neotherm is an oil/solid fuel fired thermic fluid heater in vertical / horizontal design having four heat transfer to ensure optimum efficiency. It ensures that maximum of its heating surface is exposed to radiant heat there by ensuring excellent thermal efficiency.
Efficient combustion, forced circulation, liberal heat transfer areas & large furnace volume ensures over all efficiency of 88%± 1% on N.C.V.NEOTHERM is available in wide range of capacities from 50,000 Kcals/hr to 15,00,000 Kcals/hr at maximum operating temperature of 300°C.
 
 
Technical Specifications :
Details Unit NT-50 NT-100 NT-200 NT-300 NT-400 NT-600 NT-1000 NT-1500
Operating
Parameters
                 
Capacity KCals/Hr. 50000 100000 200000 300000 400000 600000 1000000 1500000
Max. Operating Temp. (At the outlet of the unit) 0C 300 300 300 300 300 300 300 300
Fuel Oil Consumption At full load
LDO 
FO



Kgs/Hr
Kgs/Hr.



5.4
--



10.8
--

21.5
22.6





32.4
33.9



42.9
45



64.3
67.5



107.2
112.5



160.80
168.75
Efficiency (GCV) % 87+/-1 87+/-1 87+/-1 87+/-1 87+/-1 87+/-1 87+/-1 87+/-1
Burner Control

------------------------------ON---OFF------------------------------TWO STAGE

Electric Supply AC-3 Phase - 415V +/- 6%;   50 Hz,  4 Wire
Connected Elec. Load  
Thermic Fluid Pump Motor  (HP) 3 5 7.5 10 10 15 20 30
Blower Motor (HP) 1 1 1.5 2 3 5 10 10
Fuel Pump Motor   0.5 0.5 0.5 0.5 0.5 0.5 1.0 1.0
Fuel Oil Preheater (For FO Fired Units Only) KW -- -- 4.5 6.0 6.0 9.0 12 15
Total Elec. Load
For LDO Fired Units
FO Fired Units


HP

HP + KW


4.5

--


6.5

--


9.5

9.5+4.5


12.5

12.5+6


13.5

13.5+6


20.5

20.5+9


31

31+12


41

41+15
Overall Dimensions                  
Length (Mts) 2 3 4 4 4 4 4 6
Width (Mts) 2 3 4 4 4 5 5 6
Clear Height (Mts) 2.5 2.5 4 5 5 5 6 8
Fuel Gas Outlet (MM) 200 200 250 250 300 350 500 600
Gross Dry Weight (Kgs) 1000 1350 1750 2400 2900 3500 5250 6500
*  Designs and Specifications subject to changes due to constant research and development
*  The efficiency is guaranteed on the test bay with commercially clean internal and external heat transfer surfaces.
 
" NEOTHERM-C"
SOLID FUEL FIRED 3-PASS THERMIC FLUID HEATERS
SOLID FUEL FIRED 3-PASS THERMIC FLUID HEATERS
Salient Features :-
1) Three Pass Designs
2) Guaranted output with consistency
3) Efficient Heat Transfer with optimum combustion
4) External Furnace Ensures Safety of Heat Exchanger Coil
5) Truly maintenance Free
6) Low Power & Lower Fuel consumption ensures economical operation
7) Reduced excess air with balanced Draft System
8) Outside the PURVIEW of Iidian Boiler Act
9) Easy access for inspection & cleaning
10) Low system lag & rapid warm up respose
11) By-pass Damper (manual) provided to safeguard against Power Failure hazards.
12) Cost Saving Features:
• 300C at near atomspheric Pressure
• No corrossion or scale formation circuit simplicity
• Greater efficiency
Technical Specification
PARAMETERS UNIT NTC : 200 NTC : 300 NTC : 400 NTC : 600 NTC : 1000
Heat Output Kcal/hr 2,00,000 3,00,000 4,00,000 6,00,000 10,00,000
Outlet temperature (max) °C 300 300 300 300 300
Temp rise ( T) in the heater °C 25 25 25 25 25
Pressure at heater outlet Kg/cm² 2.2 2.2 2.5 2.5 2.5
Flue gas duct diameter mm 250 300 300 350 450
Inlet / Outlet connection of heater mm 50 50 65 65 100

FUEL CONSUMPTION

Coal Kgs/hr 64 96 128 192 320
Wood Kgs/hr 87 130 174 260 435
ELECTRICAL LOAD
Thermic Fluid Pump Motor Kw 5.5 5.5 7.5 11.0 15
I.D. fan motor + F.D. fan motor Kw 1.5+0.375 2.2+0.75 2.2+0.75 3.7+1.5 5+2.2
Total Connected Load Kw 7.375 8.45 10.45 16.2 22.2
 
 
 
Burners : Light Oil Burners    :-   One Stage Oil Burner   |   Two Stage Oil Burner    |   Three Stage Operation    |   
                                     Two Stage Progressive or Modulating Oil Burners    |    Single Stage and Two Stage
    Gas Oil Burners      :-    Low Nox One & Two Stage Gas Burner    |   Progressive Two Stage Modulating Gas Burners
    Heavy Oil Burners  :-    Two Stage Operatiion    |   Three Stage Heavy Oil or Modulating
    Dual Fuel Burners   :-    Gas / Light Oil Burner   |   Gas / Heavy Oil Burner
Boilers : Non-IBR Boilers    |   Nanomatic Boilers   |   Mini Steam Generators
Thermic Fluid Heaters    |   Hot Air Generators    |    Hot Water Generators    |    Tank Heating Systems    |    
Water Softner
   |    Ovens
 
Home    |   Profile    |   Products      Infrastructure    |   Our Agents    |   Contact    |   Enquiry
Designed & Hosted by : MID   Promoted by : GID