Hot Water Generators

 
Hot Water Generators
Neotech offer Riello Oil / Gas fired Hot Water Generators (Non - Pressurised)
Product Advantages :
High efficiency (>90%) with low operating cost. All parts supplied for easy installation. Low noise emission. Temperature modulation function (minimum return temperature 55°C). Combination available with domestic hot water storage cylinders / plate heat exchangers.
 
Salient Featuers :-
1) Tree Pass Design.
2) Fully automatic operation.
3) Compact, Skid Mounted
4) Imported Italian "RIELLO" Burners.
5) Energy Efficient
6) Easy operation & failsafe system
7) Qualified attendant not required.
8) Outside the purview of I.B.R.
9) Separate Boiler Room not required.
 
Characteristics of RTQ     100 130 200 300 400 600 1000 1500
Output min. kW 75 107.4 201.4 290.6 414.4 593.3 1057 1476
max.   105.3 152.9 234.3 315.6 469.1 706.3 1188 1798
min. Mcal/hr 64.5 92.36 173.2 249.92 356.38 510.24 924.5 1269.36
max.   90.56 131.49 201.5 271.42 403.426 607.418 1021.68 1546.28
Efficiency at max. output   % 91.6 92.1 91.9 90.7 91.8 92.2 93.0 92.2
Efficiency at 30% load   % 93.4 93.2 93.1 92.7 92.9 93.3

94.2

93.1
Flue gas temperature (ΔT)   °C >160 >160 >160 >160 >160 >160 >160 >160
CO2 (gas / oil)   % 9.5/12.5 9.5/12.5 9.5/12.5 9.5/12.5 9.5/12.5 9.5/12.5 9.5/12.5 9.5/12.5
Combustion chamber pressure   mbar 1.1 1.3 1.6 3.2 3.3 4.4 6.8 7.3
Combustion chamber volume   dm3 96.8 156 216 325.5 424 704 1166 1746
Total heat exchange surface   m3 2.8 4.15 6.28 8.42 12.19 17.82 27.9 43.6
Volumetric thermal load   kW/m3 1188 1064 1181 1069 1205 1088 1095 1117
Specific thermal load   kW/m3 37.6 36.8 37.3 37.5 38.5 39.6 42.6 43
Pressure drop ΔT 10°C   mbar 62.9 63.9 129 175 180 148.5 280 205
Pressure drop ΔT 20°C   mbar 15.3 17.1 28.6 51 67.5 38.5 65 52
Maximum working pressure   bar 5 5 5 5 5 5 5 5
Maximum flow temperature   °C 100 100 100 100 100 100 100 100
Maximum working temperature   °C 87 87 87 87 87 87 87 87
Minimum water return temperature   °C 55 55 55 55 55 55 55 55
Water holding Capacity   lit 109 149 187 216 430 652 1105 1432
Total weight (without Burner)   kg 233 263 443 533 835 1151 1986 2971
Details Units NH-50 NH-100 NH-200
Heat Output Kcals/hr 50,000 1,00,000 2,00,000
Max Temp. °C → 90 ←
Fuel Consumption (On continuous operation & full load basis.) HSD (Kgs / hr)
NG (Nm3 / hr)
LPG (Kgs / hr)
5.4
6.5
4.8
10.8
13
9.6
21.6
26
19.2
Burner Control   → ON - OFF ←
Pressure parts   → Outside ←
Electric Supply   AC-3 Phase-415V+/-6%, 50Hz, 4 WIRE
Connected Elec. Load        
Burner kw 0.2 0.2 0.25
Water Pump kw 0.75 1.5 2.25
Flue Gas Outlet MM 150Ø 200Ø 250Ø
Overall Dimensions. mts   1.5mts X 1.5mts 2.0mts X 1.5mts 2.5mts X 2.0mts
 
 
Burners : Light Oil Burners    :-   One Stage Oil Burner   |   Two Stage Oil Burner    |   Three Stage Operation    |   
                                     Two Stage Progressive or Modulating Oil Burners    |    Single Stage and Two Stage
    Gas Oil Burners      :-    Low Nox One & Two Stage Gas Burner    |   Progressive Two Stage Modulating Gas Burners
    Heavy Oil Burners  :-    Two Stage Operatiion    |   Three Stage Heavy Oil or Modulating
    Dual Fuel Burners   :-    Gas / Light Oil Burner   |   Gas / Heavy Oil Burner
Boilers : Non-IBR Boilers    |   Nanomatic Boilers   |   Mini Steam Generators
Thermic Fluid Heaters    |   Hot Air Generators    |    Hot Water Generators    |    Tank Heating Systems    |    
Water Softner
   |    Ovens
 
Home    |   Profile    |   Products      Infrastructure    |   Our Agents    |   Contact    |   Enquiry
Designed & Hosted by : MID   Promoted by : GID